Specifications

3516B DGB™ (50 Hz)

Specifications

Minimum Rating 1750 kVA
Maximum Rating 2275 kVA
Voltage 220 to 11000
Frequency 50 Hz
Speed 1500 rpm
Emissions/Fuel Strategy Low Fuel Consumption
Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Compression Ratio 14.0:1 Std 15.5:1 HD
Aspiration TA
Governor Type Adem™4
Fuel System Electronic unit injection
Bore 170 mm6.69 in
Displacement - HD 78.08 l4764.73 in³
Displacement - Std 69 l4210.64 in³
Stroke - HD 215 mm8.46 in
Stroke - Standard 190 mm7.48 in

3516B DGB™ (50 Hz) Standard Equipment

  • Air Inlet System
    • Air cleaner, single element canister type
  • Control System
    • EMCP 4.2
    • Emergency stop pushbutton
    • 24 Volt DC operation
    • Environmental sealed front face
    • Text alarm / event descriptions
    • Generator mounted - rear facing
    • Generator set packages include Caterpillars Voltage
    • Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
    • Limiter and exciter diode monitor
    • Controls:
    • Speed adjust
    • Auto / star t/ stop control
    • Engine cool-down timer
    • Engine cycle crank
    • Alarm acknowledge
    • Lamp test
    • Load histogram feature
    • PLC functionality
    • Customizable screens
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N), frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • kW-hr (total)
    • kVAr-hr (total)
    • Warning / shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Generator phase sequence
    • Over / under voltage (27/59)
    • Over / under frequency (81 o/u)
    • Reverse power (kW) (32)
    • Reverse reactive power (kVAr) (32RV)
    • Overcurrent (50/51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • Cat Connect
    • 3 Analog inputs
    • 6 Customer programmable digital inputs
    • Number of I/O varies on options selected:
    • 4 Programmable relay outputs (Form A)
    • 1 Programmable relay outputs (Form C)
    • 1 Programmable digital outputs
  • Cooling System
    • Package mounted radiator
  • Exhaust System
    • Dry exhaust manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Secondary fuel filters
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump
  • General
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • RH Service
    • Flywheel and Flywheel housing-SAE No. 00
    • SAE Standard Rotation
  • Generators and Attachments
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
    • 3 Phase brushless, salient pole
    • 6 lead
    • LV
    • Random wound
    • Permanent magnet
    • Winding temperature detectors
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
    • MV:
    • Form wound
    • Permanent magnet
    • Winding temperature detectors
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Bus bar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
    • HV:
    • Form wound
    • Permanent magnet
    • Winding temperature detectors
    • Anti condensation space heater
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Governing System
    • ADEM A3
  • Lube System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
  • Mounting System
    • Rails - engine / generator / radiator mounting
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts (shipped loose)
  • Starting System
    • 24 Volt electric starting motor
    • 45 Amp charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch

3516B DGB™ (50 Hz) Optional Equipment

  • Air Inlet System
    • Single element Filter
    • Dual element air cleaner
    • Optional radiator arrangements
    • Standard ambient radiators
    • Standard ambient ATAAC radiators
  • Control Panels
    • EMCP 4.3, EMCP 4.4
    • Generator main terminal box
    • Load share module
    • Digital I/O module
    • Remote monitoring software
    • Empty upper box
    • Side extension box
    • Cable Shroud
    • Annunciator - local
    • Annunciator - remote
    • Vandal proof panel cover
  • Cooling System
    • Water level switch gauges
    • Coolant
  • Crankcase Systems
    • Crankcase protection groups:
    • No explosion relief valves
    • Explosion relief valve
    • Crankcase ventilation systems
  • Exhaust System
    • Elbows>
    • Flange and exhaust expanders
    • Flanges
    • Flexible fittings
    • Y Adapters
    • Mufflers
    • Exhaust offset
    • Tier 4 lean emissions moduel
    • Tier 4 dosing cabinet
    • Tier 4 clean emission MOD kits
    • Clean emission parts
  • Extended Service Coverage
    • Platinum, Silver and Gold coverage
  • Fuel System
    • Primary fuel filter
    • Gas fuel filter
    • Fuel priming pump (Tier 4)
  • Generators and Attachments
    • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, IE, No. of leads = 6, Pitch = .6667
    • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, PM, No. of leads = 6, Pitch = .6667
    • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm ,FW, PM, No. of leads = 6, Pitch = .6667
    • 1800 Frame
    • Generators high voltage
    • 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
    • 3000 Frame - 10000, 10500, 11000 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
    • Space heater kit
    • Generator conversions
    • Hi voltage optional attachments
    • Alternator air cleaner
    • Differential current transformers
  • Instrumentation
    • Pyrometer and Termocouples
  • Lube System
    • Lube oil in standard sump
    • Oil level regulator
    • Prelube pump groups
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
  • Power Connections
    • Grounding groups
    • Neutral ground connections
    • Center post busbar
    • Right side power connections
    • Cable entry - right side
    • left side power connections
    • Cable entry - left side
    • Rear power connections
    • Cable entry - rear
  • Power Termination
    • Circuit breakers - LV packages
    • 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated circuit breakers
    • 2000, 2500, 3200 Amp, 4 Pole, IEC rated circuit breakers
    • 2000, 2500, 3200 Amp, 3 Pole, IEC rated circuit breakers
  • Special Tests / Reports
    • Seismic certifications
    • OSPD certification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard engine test
    • Generator set report
    • Fuel consumption test
    • Torsional vibration analysis
  • Starting / Charging
    • Engine barring devices
    • Batteries, racks and cables
    • 10, 20 and 35 Amp battery charger
    • 50 Amp NFPA battery charger
    • Electric starting motors
    • Air starting motors
    • Starter covers
    • Air pressure regulator
    • Jacket water heaters

Exterior

Specifications

Minimum Rating 1750 kVA
Maximum Rating 2275 kVA
Voltage 220 to 11000
Frequency 50 Hz
Speed 1500 rpm
Emissions/Fuel Strategy Low Fuel Consumption
Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Compression Ratio 14.0:1 Std 15.5:1 HD
Aspiration TA
Governor Type Adem™4
Fuel System Electronic unit injection
Bore 170 mm6.69 in
Displacement - HD 78.08 l4764.73 in³
Displacement - Std 69 l4210.64 in³
Stroke - HD 215 mm8.46 in
Stroke - Standard 190 mm7.48 in

Equipment

3516B DGB™ (50 Hz) Standard Equipment

  • Air Inlet System
    • Air cleaner, single element canister type
  • Control System
    • EMCP 4.2
    • Emergency stop pushbutton
    • 24 Volt DC operation
    • Environmental sealed front face
    • Text alarm / event descriptions
    • Generator mounted - rear facing
    • Generator set packages include Caterpillars Voltage
    • Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
    • Limiter and exciter diode monitor
    • Controls:
    • Speed adjust
    • Auto / star t/ stop control
    • Engine cool-down timer
    • Engine cycle crank
    • Alarm acknowledge
    • Lamp test
    • Load histogram feature
    • PLC functionality
    • Customizable screens
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N), frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • kW-hr (total)
    • kVAr-hr (total)
    • Warning / shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Generator phase sequence
    • Over / under voltage (27/59)
    • Over / under frequency (81 o/u)
    • Reverse power (kW) (32)
    • Reverse reactive power (kVAr) (32RV)
    • Overcurrent (50/51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • Cat Connect
    • 3 Analog inputs
    • 6 Customer programmable digital inputs
    • Number of I/O varies on options selected:
    • 4 Programmable relay outputs (Form A)
    • 1 Programmable relay outputs (Form C)
    • 1 Programmable digital outputs
  • Cooling System
    • Package mounted radiator
  • Exhaust System
    • Dry exhaust manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Secondary fuel filters
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump
  • General
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • RH Service
    • Flywheel and Flywheel housing-SAE No. 00
    • SAE Standard Rotation
  • Generators and Attachments
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
    • 3 Phase brushless, salient pole
    • 6 lead
    • LV
    • Random wound
    • Permanent magnet
    • Winding temperature detectors
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
    • MV:
    • Form wound
    • Permanent magnet
    • Winding temperature detectors
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Bus bar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
    • HV:
    • Form wound
    • Permanent magnet
    • Winding temperature detectors
    • Anti condensation space heater
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Governing System
    • ADEM A3
  • Lube System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
  • Mounting System
    • Rails - engine / generator / radiator mounting
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts (shipped loose)
  • Starting System
    • 24 Volt electric starting motor
    • 45 Amp charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch

3516B DGB™ (50 Hz) Optional Equipment

  • Air Inlet System
    • Single element Filter
    • Dual element air cleaner
    • Optional radiator arrangements
    • Standard ambient radiators
    • Standard ambient ATAAC radiators
  • Control Panels
    • EMCP 4.3, EMCP 4.4
    • Generator main terminal box
    • Load share module
    • Digital I/O module
    • Remote monitoring software
    • Empty upper box
    • Side extension box
    • Cable Shroud
    • Annunciator - local
    • Annunciator - remote
    • Vandal proof panel cover
  • Cooling System
    • Water level switch gauges
    • Coolant
  • Crankcase Systems
    • Crankcase protection groups:
    • No explosion relief valves
    • Explosion relief valve
    • Crankcase ventilation systems
  • Exhaust System
    • Elbows>
    • Flange and exhaust expanders
    • Flanges
    • Flexible fittings
    • Y Adapters
    • Mufflers
    • Exhaust offset
    • Tier 4 lean emissions moduel
    • Tier 4 dosing cabinet
    • Tier 4 clean emission MOD kits
    • Clean emission parts
  • Extended Service Coverage
    • Platinum, Silver and Gold coverage
  • Fuel System
    • Primary fuel filter
    • Gas fuel filter
    • Fuel priming pump (Tier 4)
  • Generators and Attachments
    • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, IE, No. of leads = 6, Pitch = .6667
    • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, PM, No. of leads = 6, Pitch = .6667
    • 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm ,FW, PM, No. of leads = 6, Pitch = .6667
    • 1800 Frame
    • Generators high voltage
    • 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
    • 3000 Frame - 10000, 10500, 11000 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
    • Space heater kit
    • Generator conversions
    • Hi voltage optional attachments
    • Alternator air cleaner
    • Differential current transformers
  • Instrumentation
    • Pyrometer and Termocouples
  • Lube System
    • Lube oil in standard sump
    • Oil level regulator
    • Prelube pump groups
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
  • Power Connections
    • Grounding groups
    • Neutral ground connections
    • Center post busbar
    • Right side power connections
    • Cable entry - right side
    • left side power connections
    • Cable entry - left side
    • Rear power connections
    • Cable entry - rear
  • Power Termination
    • Circuit breakers - LV packages
    • 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated circuit breakers
    • 2000, 2500, 3200 Amp, 4 Pole, IEC rated circuit breakers
    • 2000, 2500, 3200 Amp, 3 Pole, IEC rated circuit breakers
  • Special Tests / Reports
    • Seismic certifications
    • OSPD certification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard engine test
    • Generator set report
    • Fuel consumption test
    • Torsional vibration analysis
  • Starting / Charging
    • Engine barring devices
    • Batteries, racks and cables
    • 10, 20 and 35 Amp battery charger
    • 50 Amp NFPA battery charger
    • Electric starting motors
    • Air starting motors
    • Starter covers
    • Air pressure regulator
    • Jacket water heaters