Specifications

C13 (50 Hz)

Specifications

Height - Maximum 2133 mm84 in
Length - Maximum 4743 mm186.7 in
Width - Maximum 2014 mm79.3 in
Minimum Rating 350 kVA
Maximum Rating 450 kVA
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Emissions/Fuel Strategy Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards
Engine Model C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Compression Ratio 16.3:1
Aspiration Air to Air Aftercooled
Governor Type Adem™A4
Fuel System MEUI
Bore 130 mm5.12 in
Displacement 12.5 l762.8 in³
Stroke 157 mm6.18 in

C13 (50 Hz) Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable paper filter
    • Aftercooler core
    • Turbocharger
  • Control Panel
    • EMCP 4.2
  • Cooling System
    • Radiator and cooling fan with guard
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar Extended Life Coolant
  • Exhaust System
    • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generator and Attachments
    • A frame generator - IP21 Protection
    • Optional LC frame generator - IP23 Protection
    • Integrated Voltage Regulator
    • Power center, IP22
    • Segregated low voltage (AC/DC) wiring panel
    • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
  • Governing System
    • Cat Electronic Governor (ADEM A4)
  • Lube System
    • Oil Cooler
    • Lubricating oil
    • Oil drain valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting / Charging System
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

C13 (50 Hz) Optional Equipment

  • European Certificates
    • EU certificate of conformance
    • Global certificate for CIS
  • Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
  • Circuit Breakers
    • 3 Pole (IEC-100% rated) circuit breaker
    • 4 Pole (IEC-100% rated) circuit breaker
    • 3 Pole (IEC-100% rated) circuit breaker - Motorised
    • 4 Pole (IEC-100% rated) circuit breaker - Motorised
    • Circuit breaker (IEC) auxiliary contacts
    • Shunt trip for IEC circuit breaker
    • Pad-lockable circuit breaker device
    • Power terminal strip
  • Control Panels
    • Volt free contacts
    • EMCP 4.3, EMCP 4.4
    • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • Local alarm modules: Local annunciator
    • Remote annunciator modules
  • Cooling System
    • Radiator duct flange
    • Stone guards
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • Mufflers - End in / End out
    • 10, 25 and 35 dBA attenuation
    • 6 and 8 inch flange GP
    • Flexible 8 inch exhaust fittings
    • 6 and 8 inch elbow kit
  • Fuel System
    • Integral dual wall fuel tank base
    • Manual fuel transfer pump
    • Fuel transfer system controls
  • Generator and Attachments
    • Ingress protection
    • Permanent magnet generator
    • Space heaters
    • A frame oversize generator
    • A frame CIP generator
    • LC frame generator
    • LC CIP generator
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base
  • starting / Charging System
    • 5 Amp single battery charger
    • Battery disconnect switch
    • Jacket water heater

Specifications

Height - Maximum 2133 mm84 in
Length - Maximum 4743 mm186.7 in
Width - Maximum 2014 mm79.3 in
Minimum Rating 350 kVA
Maximum Rating 450 kVA
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Emissions/Fuel Strategy Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards
Engine Model C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Compression Ratio 16.3:1
Aspiration Air to Air Aftercooled
Governor Type Adem™A4
Fuel System MEUI
Bore 130 mm5.12 in
Displacement 12.5 l762.8 in³
Stroke 157 mm6.18 in

Equipment

C13 (50 Hz) Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable paper filter
    • Aftercooler core
    • Turbocharger
  • Control Panel
    • EMCP 4.2
  • Cooling System
    • Radiator and cooling fan with guard
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar Extended Life Coolant
  • Exhaust System
    • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generator and Attachments
    • A frame generator - IP21 Protection
    • Optional LC frame generator - IP23 Protection
    • Integrated Voltage Regulator
    • Power center, IP22
    • Segregated low voltage (AC/DC) wiring panel
    • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
  • Governing System
    • Cat Electronic Governor (ADEM A4)
  • Lube System
    • Oil Cooler
    • Lubricating oil
    • Oil drain valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting / Charging System
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

C13 (50 Hz) Optional Equipment

  • European Certificates
    • EU certificate of conformance
    • Global certificate for CIS
  • Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
  • Circuit Breakers
    • 3 Pole (IEC-100% rated) circuit breaker
    • 4 Pole (IEC-100% rated) circuit breaker
    • 3 Pole (IEC-100% rated) circuit breaker - Motorised
    • 4 Pole (IEC-100% rated) circuit breaker - Motorised
    • Circuit breaker (IEC) auxiliary contacts
    • Shunt trip for IEC circuit breaker
    • Pad-lockable circuit breaker device
    • Power terminal strip
  • Control Panels
    • Volt free contacts
    • EMCP 4.3, EMCP 4.4
    • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • Local alarm modules: Local annunciator
    • Remote annunciator modules
  • Cooling System
    • Radiator duct flange
    • Stone guards
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • Mufflers - End in / End out
    • 10, 25 and 35 dBA attenuation
    • 6 and 8 inch flange GP
    • Flexible 8 inch exhaust fittings
    • 6 and 8 inch elbow kit
  • Fuel System
    • Integral dual wall fuel tank base
    • Manual fuel transfer pump
    • Fuel transfer system controls
  • Generator and Attachments
    • Ingress protection
    • Permanent magnet generator
    • Space heaters
    • A frame oversize generator
    • A frame CIP generator
    • LC frame generator
    • LC CIP generator
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base
  • starting / Charging System
    • 5 Amp single battery charger
    • Battery disconnect switch
    • Jacket water heater

Related Products